Motor & Phase Rotation Testers

Triplett provides motor rotation testers, which help determine the phase wiring sequence (L1, L2, and L3) for 3-phase system installations. They are provided with color-coded test leads that can be directly connected to the motor or system under test. The testers feature LED displays, which show phase direction and clockwise and anti-clockwise phase rotation. LED displays also show the status of live phases. Our non-contact phase rotation meters are covered under a 1-year warranty. Motor and phase rotation testers are used to check the direction of motor and phase rotation in machines driven by motors and fitted with three-phase supplies.

Filters

  • Original price $209.99 - Original price $209.99
    Original price
    $209.99
    $209.99 - $209.99
    Current price $209.99

    Non-Contact Phase Rotation Tester - (PR600)

    Triplett
    In stock

    The Triplett Model PR600 Non-Contact Phase Rotation Tester determines the correct phase wiring sequence for 3-phase system installations. You can c...

    View full details
    Original price $209.99 - Original price $209.99
    Original price
    $209.99
    $209.99 - $209.99
    Current price $209.99
  • Original price $159.99 - Original price $159.99
    Original price
    $159.99
    $159.99 - $159.99
    Current price $159.99

    Motor and Phase Rotation Tester : Determines Correct Phase Wiring Sequence & Contact/Non-contact Motor-Rotation Direction - (PR450)

    Triplett
    In stock

    The Triplett Model PR450 determines correct phase wiring sequence (L1, L2, L3) for 3-phase system installations and determines contact or non-conta...

    View full details
    Original price $159.99 - Original price $159.99
    Original price
    $159.99
    $159.99 - $159.99
    Current price $159.99
  • Original price $229.99 - Original price $229.99
    Original price
    $229.99
    $229.99 - $229.99
    Current price $229.99

    Non-Contact 3 Phase Sequence and Motor Tester - (PR650)

    Triplett
    In stock

     The Triplett Model PR650 Motor and Phase Rotation Tester determines correct phase wiring sequence (L1, L2, L3) for 3-phase system installations an...

    View full details
    Original price $229.99 - Original price $229.99
    Original price
    $229.99
    $229.99 - $229.99
    Current price $229.99
  • Original price $99.99 - Original price $99.99
    Original price
    $99.99
    $99.99 - $99.99
    Current price $99.99

    Phase Rotation Tester: Determines Correct Phase Wiring Sequence for 3-Phase System Installations CATIII 600V - (PR400)

    Triplett
    In stock

    The Triplett Model PR400 determines correct phase wiring sequence (L1, L2, L3) for 3-phase system installations. Color-coded test leads are provide...

    View full details
    Original price $99.99 - Original price $99.99
    Original price
    $99.99
    $99.99 - $99.99
    Current price $99.99

Know More About Triplett Motor & Phase Rotation Testers

What is Motor rotation Testing?

Motor rotation testing plays a vital role in electrical installations and maintenance procedures by verifying the proper rotation direction of three-phase motors. This testing process is essential for identifying and addressing potential issues like incorrect wiring, reversed phases, or faulty connections. By promptly detecting and resolving these problems, motor rotation testing ensures optimal motor performance, efficiency, and overall system reliability.

What is Phase Sequence Testing?

Phase sequence testing is an essential procedure within electrical systems, particularly in three-phase installations. Its purpose is to determine the accurate sequence of phases (R, S, T) to guarantee optimal functionality and safety. By establishing the correct phase sequence, the electrical system can operate efficiently and prevent potential hazards.

How does a 3-phase rotation tester work?

The 3-phase rotation tester works on the principle of induction motors. For instance, if the motor is equipped with a three-phase supply with a phase sequence of Red, Yellow, and Blue, the motor will work in a clockwise direction. However, if the phase sequence is reversed, the motor will work in an anti-clockwise direction. This will show up on the LED display of the rotation meter.

How do you perform a phase rotation test?

The 3-phase rotation tester is used to understand if phase wiring L1, L2, and L3 is working in sequence. The meter is provided with test lead alligator clips and features test lead input jacks, L1, L2, L3 display icons, and a clockwise rotation LCD indicator with left and right icons.

Follow the below-given steps to perform a phase rotation test using a phase rotation meter.

Connect the color-coded test leads to the input jacks at the top of the meter. Connect the test probes of the meter to L1, L2, and L3 phases of the system. Turn on the device and if the connections are proper, then L1, L2, and L3 indicators will illuminate on the meter. This shows the connection of phases. Check the arrows – counter-clockwise and clockwise to understand the phase rotation of the device being tested.

What are the applications of magnetic rotation tester?

Magnetic rotation testers are used to determine the power and instrument transformer polarity. Check the continuity of electrical circuits. Identify the polarity and phase of winding sections of star and delta-connected motors.

Applications of 3-Phase Rotation Tester

A 3-phase rotation tester is a vital tool in electrical systems to determine the sequence of phases in a 3-phase power supply. Its ability to identify the correct phase rotation ensures proper and safe operation in various applications. Here are some key areas where 3-phase rotation testers find essential use:

  • Electrical Installations: During the setup of 3-phase systems, rotation testers confirm the accurate connection of phases. This prevents incorrect wiring that could lead to equipment damage, inefficient operation, or safety hazards.
  • Industrial Machinery: In manufacturing and industrial settings, 3-phase motors and machinery often require precise phase sequencing for optimal performance. Rotation testers ensure proper connections, minimizing the risk of operational issues.
  • Generator Testing: When setting up backup generators or portable generators, rotation testers verify that the generated power matches the correct phase sequence of the existing electrical system.
  • Motor and Pump Systems: In motor-driven systems like pumps, compressors, and conveyor belts, maintaining the correct phase rotation is crucial for smooth and efficient operation. The tester prevents improper connections that could lead to equipment malfunction.
  • HVAC Systems: Heating, ventilation, and air conditioning (HVAC) systems often rely on 3-phase motors. Rotation testers confirm the correct phase order in these systems to ensure optimal performance and energy efficiency.
  • Construction and Wiring: Electricians use rotation testers to verify phase connections when wiring buildings, ensuring safety compliance and preventing potential accidents due to incorrect wiring.
  • Troubleshooting: If motors or equipment are not functioning as expected, a rotation tester helps identify phase sequence issues as part of the diagnostic process.
  • Safety Checks: Periodic checks using rotation testers are part of electrical safety protocols to prevent hazardous conditions arising from incorrect phase sequencing.
  • Generator Synchronization: In scenarios where multiple generators are used in parallel, rotation testers help synchronize their phase sequences to ensure seamless integration into the electrical grid.

What are the safety procedures to follow when using a phase rotation tester?

Our magnetic rotation testers are used for live tests and designed for safe operation; however, you need to handle them with extra care to avoid electric shocks. You need to observe the following while using them.

  • Read the information in the manual carefully when using the meter.
  • Wear PPE to avoid injury from shocks or fire.
  • Check the test leads for exposed metal or damaged insulation. If any such damages are noticed, then replace the leads.
  • Avoid using the 3-phase motor rotation tester if the indicator or the test leads appear to be damaged.
  • Work carefully if you are using the magnetic rotation testers for power supplies above 42V AC peak, 30V AC RMS, 60V DC as they may pose a shock hazard.
  • Keep your fingers on the finger guards of the probes and avoid touching probe contacts.
  • Do not use the phase rotation meter around dust, vapor, or gas or moisture-laden environments.

Browse More Electrical Test & Measurement Collections

Multimeters & Clamp-On Meters:

Analog Multimeters Clamp-On Multimeters Digital Multimeters
Railroad VOM Test Sets Voltage & Current Dataloggers Magnetic Field Testers
AC Voltage Detector Continuity Testers Test Leads
Multimeter Case

Electrical Accessories:

GFCI Receptacle Testers AC Line Splitters Electrical Hand Tools
Non-Contact Voltage Detection Pens Circuit Breaker Tracers  

Megohm & Resistance Testers:

Megohmmeters - Insulation Testers Earth Ground Resistance Testers

Live Wire Circuit Testers:

Live Wire Tone & Probe Kit

Specialty:

Power Supplies